Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2016 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/25/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/19/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/15/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/11/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/08/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/05/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/05/2016 | FRAMING | Partial Approval | bistro #173, alcove 174-a, corridor 175, 175 south boxes ok, framing ok, ok for drywall | |
| 08/03/2016 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- THERE WAS NO ON SITE TO SHOW ME WHAT WAS NEED TO BE INSPECTED. * |
|
| 07/29/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/29/2016 | FRAMING | Partial Approval | ok to sheetrock D2,s.w. 5 units. ok to sheetrock laundry cieling remove sheetrock at dryer vent, repair vent. ok to sheetrock lid at dining area. |
|
| 07/28/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/22/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/18/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/11/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/05/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/28/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/22/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/20/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/03/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/20/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/18/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/16/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/11/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/29/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/27/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/20/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/16/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/14/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/12/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/11/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/06/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 04/01/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 03/30/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 03/29/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 03/24/2016 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 03/11/2016 | FRAMING | Partial Approval | OK TO SHEET ROCK SOFFITS SECTION B REHAB AREA. CHECKED PANELS AND TRANSFORMERS IN ELEC. ROOM. CHECKED HOT AND COLD WATER TO KITCHEN AND CORRIDORS. OK TO SHEET ROCK ENTRY LIDS, ENTRY RESTROOMS, ENTRY HALLWAY UP TO GYM, D2 WEST END OF WING. CHECKED PLUMBING SPA AREA AND PUBLIC RESTROOMS C2 OK TO SHEET ROCK SECTION D2 CEILINGS EAST END. STUCCO MESH OK AT COURTYARD. CHECKED GROUNDING SCREWS. REMAINDER OF ROOF DRAINS OK. OK TO TAPE SECTION D. |