Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - PROGRESS
Permit Number - T14CM05499
Inspection Description - BUILDING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/04/2015 | BUILDING - PROGRESS | Approved | IVRS - Inspection :* | |
04/08/2015 | BUILDING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
04/08/2015 | BUILDING - PROGRESS | Denied | TEMP HB REQUIRES BACKFLOW PROTECTION. INSTALL VACUUM BREAKER OR REMOVE BIB. WRAP COPPER W/ 10 MIL TO PROTECT FROM STUCCO. REMOVE CONCRETE FROM DWV, SEAL FLOOR PENETRATIONS. SLOPE AND SUPPORT CONDENSATE DRAIN. PROVIDE APPROVED SUPPORTS. SAFETY PLATES, BACKING. EXCESS FLUX RESIDUE. LAV CARRIERS. TRACER WIRE. MIN REQ COVER OVER YARDLINE. SUPPORT EXHAUST DUCT. DWV TEST |