Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T14CM04464
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/30/2014 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
11/06/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
11/05/2014 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
10/06/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
10/06/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | YARD WATER LINE TO MAIN TAP OK TO SHADE & BACK FILL | |
10/03/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
10/03/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | 1. GREASE RECEPTOR OK TO BACK FILL 2. WEST END ROLLING DOOR TRACK FOOTER OK TO POUR |
|
10/02/2014 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
09/30/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
09/30/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | 1. 2" COPPER YARD LINE FROM BLDG TO 3" PVC MAIN APPROX 40' OK TO BACK FILL 2. 2 TRENCH DRAINS TO G,R INLET U.G OK |
|
09/22/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
09/22/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | OK TO FILL BETWEEN NORTH AND WEST CLEANOUTS GREASE RECEPTORS NOT READY | |
09/19/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
09/18/2014 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
09/16/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
09/16/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | EAST PARIMETER FOOTER OK TO POUR NORTH PARIMETER DWV OK TO BACK FILL |
|
09/11/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
09/11/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | WEST END OF BLDG APPROVED | |
09/10/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
09/10/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | EAST 3 EACH FSI WITH 3" FCO SUBMIT REDLINE FOR PLUMBING EXTERIOR OF BUILDING & ALL CHANGES | |
09/09/2014 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* |