Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2014 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 09/16/2014 | ELECTRIC - RECONNECT | Partial Approval | 1. PROVIDE SEALING LOCK NUTS OR APPROVED RAIN TITE HUBS FOR SIDE TERMINATION 3/4" CONDUITS INTO PANEL 2. 1" SEAL TITE TO BE RE-ROUTED AROUND WINDOW NO ANSWER AT DOOR NO MSG |
|
| 08/28/2014 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 07/11/2014 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/11/2014 | ELECTRIC - RECONNECT | Denied | - MISSING SMOKED DETECTORS IN HALLWAYS AND BEDROOMS - ELECTRICAL CABELING DONE INSIDE DWELLING IN A HAZADOUS WAY, NOT TO CODE - SERVICE IN NEED OF UPGRADE, NOT RATED FOR EXTERIOR, HAS WATER DAMAGE INSIDE ENCLOSER-DOUBLE LUGGING ON LINE SIDE, NO GROUNDING ELECTRODE SYSTEM - WIRING AROUND OUTSIDE BACK NOT TO CODE OBTAIN THE SERVICE OF A LICENCED CONTRACTOR TO MAKE REPAIS, REVISE PERMIT FOR SERVICE UPGRADE |