Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14CM03978

Parcel: 13414018N


Addresses:

7503 E 22ND ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T14CM03978

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/23/2015 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/18/2015 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
02/06/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
02/06/2015 PLUMBING - ROUGH, SOIL Partial Approval MANHOLE PRESSURE TEST/4" LINE - OK @ 4.5 PSI
02/05/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
02/05/2015 PLUMBING - ROUGH, SOIL Partial Approval 6" WASTE LINE @ WEST ENTRY TO NORTH MANHOLE - OK TO COVER PROGRESS AREA
02/03/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
02/03/2015 PLUMBING - ROUGH, SOIL Partial Approval 6" WASTE LINE CONNECTION @ WEST ENTRY AREA - OK TO COVER
01/30/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
01/30/2015 PLUMBING - ROUGH, SOIL Partial Approval 6" WASTE LINE - "RIDE NOW" TO PRUDENCE RD - OK TO COVER
01/29/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
01/29/2015 PLUMBING - ROUGH, SOIL Partial Approval 6" WASTE LINE FROM RIDE-NOW MAIN ENTRY AREA TO PRUDENCE ROAD - OK TO COVER
01/21/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
01/21/2015 PLUMBING - ROUGH, SOIL Partial Approval 1. FROM MANHOLE TO 2ND CLEANOUT U.G. OK
2. WATER & ELECTRIC EXISTING OK
01/15/2015 PLUMBING - ROUGH, SOIL Partial Approval VENTS AND DISCHARGE LINES FOR GREASE INTERCEPTOR IN MAINTENANCE AREA
01/06/2015 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
01/06/2015 PLUMBING - ROUGH, SOIL Partial Approval 2" & 4" WASTE AND VENT LINES IN RMS # 105,106,107,110; EXCEPT FOR 4" CLEAN OUT CLEAN OUT MUST HAVE "Y" PIPING TO EFFECT PROPER CLEAN OUT
12/31/2014 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
12/31/2014 PLUMBING - ROUGH, SOIL Partial Approval 2" WATERLINE FROM EAST ENTRY TO RIDE NOW - NORTH TO MAIN HOOK-UP - OK TO COVER
12/23/2014 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
12/23/2014 PLUMBING - ROUGH, SOIL Partial Approval 3" WATERLINE FROM BUILDING TO MID POINT OF RIDE-NOW PARKING LOT - OK TO COVER PROGRESS AREA
12/22/2014 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
12/22/2014 PLUMBING - ROUGH, SOIL Partial Approval 6" WASTE LINE FROM BUILDING TO MID-PARKING LOT - 4" WASTE CLEAN-OUTS - APPROX 300'
12/19/2014 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*