| 06/23/2015 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 02/19/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 02/18/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/18/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GATE ARCH @ 32'-36' | |
| 02/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU COLUMNS @ 8'-12'; GL: F/4-6; .5/C-D.5; CMU WALL @ 16'-20'; GL: 1/D-E; CMU WALL @ 20'-24'; GL: 6/D-E; GATE/ARCH AREA @ GL: A/.25-1 @ 28' 4"-32' (GROUTED) | |
| 02/11/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/11/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SOUTH WALL @ GL: E/1-6, RAKED @ 20' - 32'; WEST WALL @ GL: 1/C.25-D, 8' - 12'; WALLS @ 0' - 4' GL: 1/D-D.25; 1/D.4-D.6; 1/D.7-D.75 - OK TO GROUT PROGRESS AREAS | |
| 02/09/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/09/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GATE/ARCHWAY WALLS @ 8-12'; CMU WALL @ 0'-4' GL: 1/D.3-.5 - OK TO GROUT | |
| 02/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GATE COLUMNS @ 12' - OK TO GROUT | |
| 02/04/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/04/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | EAST WALL TOPPED-OUT @ 25' GL: 6/D.5-E; NORTH WALL @ 22' GL: E/5-6; @ 24' E/3-5; @ 22'-24' (RAKED) E/1-3 - OK TO GROUT PROGRESS AREAS; MASONRY COLUMNS @ 4'-8' GL: .5/C; .5/D - OK TO GROUT | |
| 01/30/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 01/30/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | E CMU WALL @ 16'-20' GL: 6/D.25-E; NORTH WALL GL; E/1-6; EXTERIOR COLUMNS @ 4'-8' - OK TO GROUT PROGRESS AREAS | |
| 01/28/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 01/28/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GATE WALLS & COLUMNS AT 4'-8' (SOLID GROUT); 5 COLUMNS @ 0'-4'; GL: .5/C-F; 5 COLUMNS @ GL: F/1-6 - OK TO GROUT PROGRESS AREA | |
| 01/22/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 01/22/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | - OK TO GROUT 8'-12' ON GRIDLINE "E" & "6" - OK TO GROUT 0'-4' ON "A" EASTSIDE ONLY |
|
| 01/16/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 01/16/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS @ 0'-4' AFFE GL: 6/D-E; E/1-6; 1/D.2-E - OK TO GROUT PROGRESS AREAS |