Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/05/2015 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 03/04/2015 | BUILDING - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* |
|
| 03/04/2015 | BUILDING - FINAL | Denied | NO ACCESS. DOOR LOCKED | |
| 03/03/2015 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/03/2015 | BUILDING - FINAL | Denied | FINISH CONNECTING WATER HEATER. PROVIDE A DISCONNECT AT WATER HEATER. PROVIDE A LOOP IN DISHWASHER HOSE. PROVIDE HAMMER ARRESTORS AT LAUNDRY. PROVIDE ANTI-TILT DEVICE AT STOVE. CONNECT DRAIN AT KITCHEN SINK. SEAL WALL OPENING AT DRAIN UNDER BOTH SINKS. SECURE WATER HEATER DRAIN LINE FROM PAN. PROVIDE A SCREEN IN BATH EXHAUST T-TOP. SECURE THE A/C STAND TO ROOF. WILL CHECK CORRECTIONS ON BUILDING FINAL. |