Permit: T14CM03195

Parcel: 13323164A


Addresses:

7150 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T14CM03195

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
06/13/2016 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
06/07/2016 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :23See detailed listing on site.| 99946
*
04/05/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/04/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/30/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/11/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/08/2016 REINFORCED MASONRY PRE-GROUT Partial Approval trash compactor
03/03/2016 REINFORCED MASONRY PRE-GROUT Partial Approval
03/01/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/29/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/26/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/25/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/24/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/22/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/19/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/18/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/10/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/09/2016 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
02/08/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/04/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/03/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
01/26/2016 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/20/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/16/2015 REINFORCED MASONRY PRE-GROUT Partial Approval FRONT WALL PER S2.3 PROVIDE SPEC INSP REPORT
10/15/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/15/2015 REINFORCED MASONRY PRE-GROUT Partial Approval NORTH WALL AND S. CORNER OF EXPANSION
08/28/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/27/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/26/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/24/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/20/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/20/2015 REINFORCED MASONRY PRE-GROUT Partial Approval 1ST COURSE SOUTH HALF
08/17/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/14/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/14/2015 REINFORCED MASONRY PRE-GROUT Partial Approval TO 16' NORTH OF COL H
08/13/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/13/2015 REINFORCED MASONRY PRE-GROUT Partial Approval 3 RD LIFT NORTH AND NORTHEAST WALLS
08/11/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/11/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CHRIS SOTO W/ ???. SPECIAL INSPECTION REPORTS ON SITE. 2ND LIFT OK
08/10/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/10/2015 REINFORCED MASONRY PRE-GROUT Partial Approval CALL FOR DAILY PRE-GROUT INSPECTIONS. ALSO, SPECIAL INSPECTION REPORTS REQUIRED
08/06/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/22/2015 REINFORCED MASONRY PRE-GROUT Partial Approval AT NORTH EXPANSION VERTICAL STEEL NOT EXTENDED TO TOP OF BOND BEAMS. OK TO GROUT FINAL LIFT AFTER SPECIAL INSPECTOR CONFIRMS VERTICAL STEEL HAS BEEN CORRECTED
06/17/2015 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT 6TH LIFT AT NORTH EXPANSION
06/16/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/16/2015 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT 5TH LIFT AT NORTH EXPANSION
06/12/2015 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT 4TH LIFT AT NORTH EXPANSION
06/10/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/10/2015 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT 3RD LIFT AT NORTH EXPANSION
06/09/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/09/2015 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT 2ND LIFT AT NORTH EXPANSION
06/05/2015 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/05/2015 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT 1ST LIFT AT NE EXPANSION