Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T14CM03195
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2016 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 06/07/2016 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection :23See detailed listing on site.| 99946 * |
|
| 04/05/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 04/04/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 03/30/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 03/11/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 03/08/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | trash compactor | |
| 03/03/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 03/01/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/29/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/26/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/25/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/24/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/22/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/19/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/18/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/10/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/09/2016 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 02/08/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/04/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/03/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 01/26/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 10/20/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 10/16/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | FRONT WALL PER S2.3 PROVIDE SPEC INSP REPORT | |
| 10/15/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 10/15/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | NORTH WALL AND S. CORNER OF EXPANSION | |
| 08/28/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/26/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/24/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/20/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/20/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1ST COURSE SOUTH HALF | |
| 08/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/14/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/14/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TO 16' NORTH OF COL H | |
| 08/13/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/13/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 3 RD LIFT NORTH AND NORTHEAST WALLS | |
| 08/11/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/11/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CHRIS SOTO W/ ???. SPECIAL INSPECTION REPORTS ON SITE. 2ND LIFT OK | |
| 08/10/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 08/10/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CALL FOR DAILY PRE-GROUT INSPECTIONS. ALSO, SPECIAL INSPECTION REPORTS REQUIRED | |
| 08/06/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 06/22/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | AT NORTH EXPANSION VERTICAL STEEL NOT EXTENDED TO TOP OF BOND BEAMS. OK TO GROUT FINAL LIFT AFTER SPECIAL INSPECTOR CONFIRMS VERTICAL STEEL HAS BEEN CORRECTED | |
| 06/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 6TH LIFT AT NORTH EXPANSION | |
| 06/16/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 06/16/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 5TH LIFT AT NORTH EXPANSION | |
| 06/12/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 4TH LIFT AT NORTH EXPANSION | |
| 06/10/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 06/10/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 3RD LIFT AT NORTH EXPANSION | |
| 06/09/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 06/09/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 2ND LIFT AT NORTH EXPANSION | |
| 06/05/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 06/05/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | OK TO GROUT 1ST LIFT AT NE EXPANSION |