Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/28/2014 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/25/2014 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 11/25/2014 | BUILDING - FINAL | Partial Approval | the circuit brkrs used are not listed for this panel and are nopt arc fault breakers 1 receptacle is not tamper proof. provide panel schedule |
|
| 11/13/2014 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 11/13/2014 | BUILDING - FINAL | Partial Approval | DO NOT US PLASTIC HOSE OUTDOORS FOR CONDENSATE PROVIDE A PROTECTIVE COATING ON EXPOSED ARM FLEX NO TAPE PROVIDE PROPER FUSING AT CONDENSOR PROVIDE TAMPER PROOF RECEPTACLE & ARC FAULT SUB PANEL SEPERATE GROUNDS & NEUTRAL IN SUB PANEL |