| 07/18/2014 | FRAMING | Approved | ||
| 06/20/2014 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/19/2014 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 06/19/2014 | FRAMING | Denied | REVISE DRAWINGS TO SHOW LEDGERS ATTACHED TO BEAMS AT CARPORT ENTRANCE AND AT STORAGE WALL. SHOW DETAIL ON DRAWINGS SHOWING CONNECTION OF ROOF JOIST TO EXISTING HOUSE. MAY NEED COLUMN TO TRANSFER BEARING LOAD TO GROUND (NE CORNER). NOT FRAMED ACCORDING TO APPROVED PLANS. |