Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T14CM01956

Parcel: 110111060


Addresses:

4942 E GLENN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/18/2014 FRAMING Approved
06/20/2014 FRAMING Partial Approval IVRS - Inspection :*
06/19/2014 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/19/2014 FRAMING Denied REVISE DRAWINGS TO SHOW LEDGERS ATTACHED TO BEAMS AT CARPORT ENTRANCE AND AT STORAGE WALL. SHOW DETAIL ON DRAWINGS SHOWING CONNECTION OF ROOF JOIST TO EXISTING HOUSE. MAY NEED COLUMN TO TRANSFER BEARING LOAD TO GROUND (NE CORNER). NOT FRAMED ACCORDING TO APPROVED PLANS.