Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/14/2014 PLUMBING - INTERMEDIATE Approved
04/09/2014 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/09/2014 PLUMBING - INTERMEDIATE Not ready for Inspection **INCOMPLETE INSPECTION**
1. COMPLETE W/H T & P LINE, PROVIDE PAN UNDER W/H. PROVIDE METAL SUPPLY LINES AT W/H 18" SUPPORT PEX THROUGHOUT. PROVIDE NAIL PLATES PROVIDE MAIN SHUTOFF VALVE.
2. PROVIDE TEST GAUGE WITH TENTH POUND INCREMENTS