Permit: T14CM01574

Parcel: 130051170


Addresses:

1823 S AMALIA AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/15/2014 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/21/2014 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/21/2014 ELECTRIC - FINAL Denied 1. EXPOSED ROMEX BELOW ROOF FOR 24 OV OUTLET
2. WATER HEATER FLUE PIPE NEEDS 1" CLEARANCE AROUND PLYWOOD ROOF DECK
3. INSTALL CIRCUIT BREAKER BLANKS ON SERVICE PANEL DEADFRONT COVER. ALSO, RE-SUPPORT PANEL, REMOVE PVC PIPE, & PLUG HOLE AT BOTTOM OF PANEL
4. COOLER NOT WIRED TO CODE
5. SHED IN BACKYARD WIRING UNSAFE, NOT TO CODE
6. FAN WIRING ON PORCH NOT TO CODE
7. SMOKE DETECTOR MISSING N.E. BEDROOM
**USE LICENSED ELECTRICIAN TO MAKE REPAIRS**