Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14CM01560

Parcel: 117030620


Addresses:

339 E UNIVERSITY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T14CM01560

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/23/2014 PLUMBING - FINAL Approved IVRS - Inspection :*
03/25/2014 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/25/2014 PLUMBING - FINAL Denied VENT CONNECTOR HAS BACK PITCH, 1/4" PER FOOT SLOPE IS REQUIRED. ASBESTOS VENT IS NO LONGER AN APPROVED MATERIAL, PROVIDE TYPE "B" VENT. A CARBON MONOXIDE DETECTOR IS REQUIRED INSIDE HOME. **NOTE: FURNACE REQS INSPECTION. VENT CONNECTOR IS NOT PROPERLY INSTALLED**