Permit: T14CM01547

Parcel: 12302248B


Addresses:

2520 E LESTER ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/07/2015 BUILDING - FINAL Approved
07/21/2015 BUILDING - FINAL Denied STRAP DISHWASHER LOOSE TO BOTTOM OF COUNTERTOP. PROVIDE HAMMER ARRESTORS AT LAUNDRY FAUCETS. CAULK TOILETS. DRAIN LEAKING AT BATHROOM SINK. PROVIDE A SEDIMENT TRAP AT WATER HEATER. PROVIDE ARC FAULT BREAKERS PERCODE. PROVIDE AIR ADMITTANCE VALVE AT OUTDOOR SINK. PROVIDE VACUUM BREAKER AT HOSE BIB& BREAK OFF SET SCREW. PROVIDE TAMPER PROOF RECEPTACLES. PROVIDE ACCESS TO ROOF. REMOVE FLEX FROM T&P DRAIN.
DRAIN MUST SLOPE DOWN.