Permit: T14CM01533

Parcel: 112043380

Inspection Status: Approved

Inspection History: STUCCO MESH

Date Description Inspector Results Comments
09/17/2014 STUCCO MESH Approved
07/15/2014 STUCCO MESH Denied 1. WRONG WEEP SCREED ON STUCCO MESH AND NOT PROPER CLEARANCE TO SLAB, ALONG WITH THE WRONG STAPLES AND WRONG FASTENER SPACING.
2. A PERMANENT WATER SEAL MUST BE DEVISED AND INSTALLED AROUND THE ENTIRE PERIMETER OF THE ADDITION, AS THE SLAB IS IMPROPERLY PITCHED TOWARD THE HOUSE.
3. NO MECHANICAL PLAN ON SITE.
NOTE: DUE TO THE NUMEROUS PROBLEMS WITH THIS ADDITION, I RECOMMEND THAT YOU HIRE A LICENSED CONTRACTOR TO AT LEAST GUIDE YOU THROUGH THE JOB, IF NOT TO DO THE WORK ALSO.