Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T14CM01339

Parcel: 132180310


Addresses:

1126 E TENNESSEE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/07/2014 FRAMING Approved IVRS - Inspection :*
09/30/2014 FRAMING Partial Approval IVRS - Inspection :*
09/30/2014 FRAMING Partial Approval 1.NO UNIONS IN GAS LINE IN WALL BEHIND CABINET
2.PROVIDE TRIMMERS AT WINDOW
3.USE ALL NAIL HOLES IN H-2.5
4.PROVIDE BUSHING AT ELEC. K.O.
5.PROVIDE DOUBLE PLATE AT LEAD WALL PER PLAN