Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14CM01254

Parcel: 140418670

Inspection Status: Not ready for Inspection

Inspection History: STEM WALL/RETAINING WALL

Permit Number - T14CM01254

Inspection Description - STEM WALL/RETAINING WALL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
01/08/2015 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
12/23/2014 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
12/23/2014 STEM WALL/RETAINING WALL Not ready for Inspection CONTRACTOR CANCELED
12/22/2014 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
12/22/2014 STEM WALL/RETAINING WALL Not ready for Inspection WILL RECALL
12/16/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
12/16/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALLS FOR ADMIN AREA: GL: 5.5/G-H, H/5.5-7, 7/G-H - OK TO POUR PROGRESS AREA
12/03/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
12/03/2014 STEM WALL/RETAINING WALL Partial Approval CONCRETE CURB & GUTTER - WESTSIDE OF SITE; DETAILS #3 & #4, PAGE 20 - OK TO POUR PROGRESS AREA
11/26/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
11/26/2014 STEM WALL/RETAINING WALL Partial Approval 5@ COLUMN PIERS: GL-6.5/G-H(3) G/g-h(2); 2 LIGHT POLE CAISSON FOOTING-S&SW OK TO POUR
10/31/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
10/31/2014 STEM WALL/RETAINING WALL Partial Approval APPROX 60' OF 56' STEM WALL @ GL: A/5.5 OK TO POUR
10/30/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
10/30/2014 STEM WALL/RETAINING WALL Partial Approval 6@ LIGHT POLE CAISSON FOOTINGS; GROUNDING SYSTEM IN SERIES:OK TO POUR PROGRESS AREAS
10/27/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
10/27/2014 STEM WALL/RETAINING WALL Partial Approval SCREEN WALL FOOTING AT GL: A/5.5 OK TO POUR 11 @ COLUMN PROTECTOR FOOTINGS: 5 @ F/7-11 4 @ E/7-10; 2 @ D/9-10; E/8 HOLE IN TUBE (PATCH OR REPL TUBE) OK TO POUR PROGRESS AREAS
10/24/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
10/24/2014 STEM WALL/RETAINING WALL Partial Approval 5 COLUMN PROTECTION CAISSON FOOTINGS OK TO POUR
10/16/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
10/16/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALL FOOTING-GL: 17/F.4-G:G/16-17-21 @ BOLLARDS AT GL:G/5.5-16: OK TO POUR PROGRESS AREAS
10/09/2014 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
10/09/2014 STEM WALL/RETAINING WALL Not ready for Inspection CONTRACTOR CANCELLED- RAINED OUT
10/03/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
10/03/2014 STEM WALL/RETAINING WALL Partial Approval STEM FOOTINGS @ GL: G/14-16 STEM WALL @ GL: A/16-17; 17/A-C; 1/F.4-G, G/1-1.4: OK TO POUR PROGRESS AREAS
10/01/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
10/01/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALL FOOTING AT GL:G/13.5-14. OK TO POUR PROGRESS AREA
09/30/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/30/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALL; APPROX 152' @GL:A/13.5-16 OK TO POUR PROGRESS AREAS
09/26/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/26/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALL @ GL: G/11.7-13.5 COLUMN PEDISTALS; 5@ GL:15-B-F; 5@ GL:16/B-F OK TO POUR
09/25/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/25/2014 STEM WALL/RETAINING WALL Partial Approval APPROX 157' OF STEM WALL @ GL: A/10.5-13.7 OK TO POUR PROGRESS AREA
09/23/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/23/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALL @ GL; G/9.5-11.2
09/19/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/19/2014 STEM WALL/RETAINING WALL Partial Approval GL: A/8.5-10.5
09/16/2014 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
09/15/2014 STEM WALL/RETAINING WALL Partial Approval GL; A/6-8.5; OK TO POUR
09/12/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/05/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/05/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALL @ STEP-DOWN GL: A/5.5-6 - OK TO POUR PROGRESS AREA. COLUMN FOOTING (F5-5) @ GL: G/4
09/03/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
09/03/2014 STEM WALL/RETAINING WALL Partial Approval STEM WALL FOOTINGS @ GL: A/5.5-11.5. THIS AREA POURED 8-29; SPECIAL INSPECTED; GL: A/12-16. OK TO POUR PROGRESS AREA.
08/18/2014 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*