| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2015 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 12/23/2014 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 12/23/2014 | STEM WALL/RETAINING WALL | Not ready for Inspection | CONTRACTOR CANCELED | |
| 12/22/2014 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 12/22/2014 | STEM WALL/RETAINING WALL | Not ready for Inspection | WILL RECALL | |
| 12/16/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 12/16/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALLS FOR ADMIN AREA: GL: 5.5/G-H, H/5.5-7, 7/G-H - OK TO POUR PROGRESS AREA | |
| 12/03/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 12/03/2014 | STEM WALL/RETAINING WALL | Partial Approval | CONCRETE CURB & GUTTER - WESTSIDE OF SITE; DETAILS #3 & #4, PAGE 20 - OK TO POUR PROGRESS AREA | |
| 11/26/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 11/26/2014 | STEM WALL/RETAINING WALL | Partial Approval | 5@ COLUMN PIERS: GL-6.5/G-H(3) G/g-h(2); 2 LIGHT POLE CAISSON FOOTING-S&SW OK TO POUR | |
| 10/31/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 10/31/2014 | STEM WALL/RETAINING WALL | Partial Approval | APPROX 60' OF 56' STEM WALL @ GL: A/5.5 OK TO POUR | |
| 10/30/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 10/30/2014 | STEM WALL/RETAINING WALL | Partial Approval | 6@ LIGHT POLE CAISSON FOOTINGS; GROUNDING SYSTEM IN SERIES:OK TO POUR PROGRESS AREAS | |
| 10/27/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 10/27/2014 | STEM WALL/RETAINING WALL | Partial Approval | SCREEN WALL FOOTING AT GL: A/5.5 OK TO POUR 11 @ COLUMN PROTECTOR FOOTINGS: 5 @ F/7-11 4 @ E/7-10; 2 @ D/9-10; E/8 HOLE IN TUBE (PATCH OR REPL TUBE) OK TO POUR PROGRESS AREAS | |
| 10/24/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 10/24/2014 | STEM WALL/RETAINING WALL | Partial Approval | 5 COLUMN PROTECTION CAISSON FOOTINGS OK TO POUR | |
| 10/16/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 10/16/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALL FOOTING-GL: 17/F.4-G:G/16-17-21 @ BOLLARDS AT GL:G/5.5-16: OK TO POUR PROGRESS AREAS | |
| 10/09/2014 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 10/09/2014 | STEM WALL/RETAINING WALL | Not ready for Inspection | CONTRACTOR CANCELLED- RAINED OUT | |
| 10/03/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 10/03/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM FOOTINGS @ GL: G/14-16 STEM WALL @ GL: A/16-17; 17/A-C; 1/F.4-G, G/1-1.4: OK TO POUR PROGRESS AREAS | |
| 10/01/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 10/01/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALL FOOTING AT GL:G/13.5-14. OK TO POUR PROGRESS AREA | |
| 09/30/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/30/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALL; APPROX 152' @GL:A/13.5-16 OK TO POUR PROGRESS AREAS | |
| 09/26/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/26/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALL @ GL: G/11.7-13.5 COLUMN PEDISTALS; 5@ GL:15-B-F; 5@ GL:16/B-F OK TO POUR | |
| 09/25/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/25/2014 | STEM WALL/RETAINING WALL | Partial Approval | APPROX 157' OF STEM WALL @ GL: A/10.5-13.7 OK TO POUR PROGRESS AREA | |
| 09/23/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/23/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALL @ GL; G/9.5-11.2 | |
| 09/19/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/19/2014 | STEM WALL/RETAINING WALL | Partial Approval | GL: A/8.5-10.5 | |
| 09/16/2014 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/15/2014 | STEM WALL/RETAINING WALL | Partial Approval | GL; A/6-8.5; OK TO POUR | |
| 09/12/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/05/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/05/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALL @ STEP-DOWN GL: A/5.5-6 - OK TO POUR PROGRESS AREA. COLUMN FOOTING (F5-5) @ GL: G/4 | |
| 09/03/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 09/03/2014 | STEM WALL/RETAINING WALL | Partial Approval | STEM WALL FOOTINGS @ GL: A/5.5-11.5. THIS AREA POURED 8-29; SPECIAL INSPECTED; GL: A/12-16. OK TO POUR PROGRESS AREA. | |
| 08/18/2014 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* |