Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T14CM01114
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/11/2014 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
02/28/2014 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
02/27/2014 | ELECTRIC - FINAL | Denied | PROVIDE A SMOKE DETECTOR IN EACH BEDROOM AS PER MANUFACTURERS INSTALL INSTRUCTIONS. CAP-OFF OPEN CONDUCTORS IN CEILING IN 1 BEDROOM. THE RECEPTACLE AT FRONT OF HOUSE MUST BE GFI. ROMEX IS NOT APPROVED FOR DIRECT BURIAL TO LIGHT IN FRONT YARD - REMOVE OR WIRE PER CODE. TRIM BACK THE BUSH BLOCKING ACCESS TO PANEL AND ALLOW MIN 3' OF CLEAR SPACE IN FRONT OF PANEL. SECURE THE ROMEX TO THE RECEPTACLE IN STORAGE SHED. |