Permit: T14CM01033

Parcel: 121021080


Addresses:

5650 E LESTER ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/17/2014 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/25/2014 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/25/2014 ELECTRIC - FINAL Denied PROVIDE A SMOKE DETECTOR IN EACH BEDROOM. INSTALL DETECTORS MIN 3' FROM AIR VENTS AND CEILING FAN BLADES. THE DETECTOR IN HALLWAY DOES NOT WORK. REMOVE ABANDONED RECEPTACLE ON PATIO OR PROPERLY INSTALL. FILL IN OPENING WHERE BREAKER IS MISSING IN PANEL AT REAR OF GARAGE. SECURE MC CONDUITS IN GARAGE. SECURE THE DEADFRONT FOR SUBPANEL. REMOVE ANY 3-PRONG RECEPTACLES CONNECTED TO A NON-GROUNDED SYSTEM. THE RECEPTACLE IN PATIO WALL NEEDS TO BE GFI.