Permit: T14CM01025

Parcel: 11107227B


Addresses:

2712 N FLANWILL BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/03/2014 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
10/01/2014 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/01/2014 PLUMBING - INTERMEDIATE Not ready for Inspection OK- PROVIDE TEST. WRAP PIPES FOR CONCRETE
09/02/2014 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/29/2014 PLUMBING - INTERMEDIATE Denied PROVIDE DRAINAGE FITTINGS installed as required.
VENT 90 DEGREE NOT ALLOWED FOR DRAINAGE SANT T.
VENT TRUSS CALCS FOR MECHANICAL UNIT AND INSTRUCTIONS FOR HANGING UNIT. SECURE VENT WITH SCREWS. CORRECT INSULATION
COMPLETE NOTED CORRECTIONS
TEST ALL JOINTS
METAL RACEWAY FOR FUTURE SOLAR
PROVIDE CITY APPROVED PLANS
08/21/2014 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/21/2014 PLUMBING - INTERMEDIATE Denied PROVIDE GUY WIRES FOR ELECTRIC SERVICE. UFER REQS ACCESS. FUTURE SOLAR - TRUSS NOT DESIGNED TO SUPPORT MECH HOUSE BIB VACUUM BREAKER. YARD LINE (TEMP CONN) 12" COVER REQUIRED. DWV REQUIRES PROPER USE OF DRAINAGE FITTINGS. POINT OF VENT MAY NOT BE BELOW TRAP WELD. TEST ALL SYSTEMS, FITTINGS, FIXTURES. PROVIDE A SOLVENT WELD WASTE AND OVERFLOW KIT FOR TUB. IT IS NOT ADVISED TO OFFSET TUB TAIL PIECE. NO PIPING MAY BE EMBEDDED IN CONCRETE. PROVIDE MIN 18 OF COPPER AT WH PEX CONN. 4" SAFETY PLATES REQ AT PLUMBING & MECHANICAL. PVC REQ PRIMER. INSTALL PROPER SUPPORTS. SINGLE WALL VENT REQ 6" CIR. INSPECTION STOPPED