Permit: T14CM00767

Parcel: 110160280


Addresses:

2451 N SONOITA PL

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/25/2014 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/11/2014 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/11/2014 ELECTRIC - FINAL Denied THE OUTDOOR RECEPTACLES ON PATIO & WESTSIDE OF HOUSE NEED TO BE GFI W/ WATERPROOF COVERS. INSTALL THE SMOKE DETECTORS PER MANUFACTURERS ISNTRUCTIONS. THE ONE IN THE HALLWAY IS MISSING THE BATTERY AND ONLY ATTACHED WITH ONE SCREW. COVERPLATE MISSING AT RECEPTACLE IN LIVINGROOM. REMOVE THE CORD & PLUG CEILING FAN IN BEDROOM OR HARDWIRE PER CODE & INSTALL INSTRUCTIONS. THE RECEPTACLE AT CARPORT ALSO NEEDS TO BE GFI. REMOVE THE ELECTRICAL DEVICE THAT IS CONNECTED TO THE FRONT PORCH LIGHT OR USE PROPER WIRING METHODS.