Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/25/2014 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 02/11/2014 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/11/2014 | ELECTRIC - FINAL | Denied | THE OUTDOOR RECEPTACLES ON PATIO & WESTSIDE OF HOUSE NEED TO BE GFI W/ WATERPROOF COVERS. INSTALL THE SMOKE DETECTORS PER MANUFACTURERS ISNTRUCTIONS. THE ONE IN THE HALLWAY IS MISSING THE BATTERY AND ONLY ATTACHED WITH ONE SCREW. COVERPLATE MISSING AT RECEPTACLE IN LIVINGROOM. REMOVE THE CORD & PLUG CEILING FAN IN BEDROOM OR HARDWIRE PER CODE & INSTALL INSTRUCTIONS. THE RECEPTACLE AT CARPORT ALSO NEEDS TO BE GFI. REMOVE THE ELECTRICAL DEVICE THAT IS CONNECTED TO THE FRONT PORCH LIGHT OR USE PROPER WIRING METHODS. |