Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T14CM00534
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/03/2014 | PLUMBING - FINAL | Approved | ||
01/30/2014 | PLUMBING - FINAL | Not ready for Inspection | 1. Support all gas piping. resting on bricks not accepted. Water heater vent not connected. Note: Several water heater violations to be addressed when changing water heater- T&P relief drain to extend to the outside. water heater requires a shut off at the cold inlet. Requires a pan and a drain. |