Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/03/2014 |
PLUMBING - FINAL |
|
Approved |
|
| 01/30/2014 |
PLUMBING - FINAL |
|
Not ready for Inspection |
1. Support all gas piping. resting on bricks not accepted. Water heater vent not connected. Note: Several water heater violations to be addressed when changing water heater- T&P relief drain to extend to the outside. water heater requires a shut off at the cold inlet. Requires a pan and a drain. |