Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/17/2014 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
01/17/2014 PLUMBING - FINAL Partial Approval - PROVIDE SEDIMENT TRAPS @ APPLIANCES
- INSTALL SMOKE DETECTORS IN BEDROOMS AND HALLWAYS
- INSTALL CO DETECTOR IN HALLWAY
01/16/2014 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
01/16/2014 PLUMBING - FINAL Not ready for Inspection 1. PRESS TEST FAIL
2. PROVIDE T & P TERMINATION & PAN
3. C.O. DETECTOR
4. FLUE AT W/H NOT PROPERLY TERMINATED