Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T14CM00059
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/17/2014 | PLUMBING - FINAL | Approved | ||
| 01/09/2014 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/09/2014 | PLUMBING - FINAL | Denied | WATER HEATER REQUIRES; SCREWS IN VENT PIPE JOINTS, CLEARANCE FROM COMBUSTIBLES AT ROOF PENETRATION, A DRAIN PAN, BECAUSE OF WOOD PLATFORM AND A GAS PIPE SEDIMENT TRAP. ROOFTOP FURNACE REQ; SUPPORT GAS PIPE, INSTALL SEDIMENT TRAP, CORRECT CONDENSATE, CORRECT ELECTRICAL CONDUIT CONNECTIONS, & SUPPORT CONDUITS. CODE REQ CARBON MONOXIDE DETECTOR. CLEARANCE PROVIDED. |
|
| 01/08/2014 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 01/08/2014 | PLUMBING - FINAL | Partial Approval | - PROVIDE LADDER FOR ROOF INSPECTION OF GAS LINE. - ALSO NEED ACCESS INTO DWELLING FOR APPLIANCE CONNECTIONS - NO ANSWER AT DOOR. - GAS PRESSURE TEST OK **RESCHEDULE INSPECTION** |
|
| 01/07/2014 | PLUMBING - FINAL | Denied | SEE GAS PRESSURE TEST COMMENTS |