Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T14CM00018

Parcel: 116300220

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
05/01/2014 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
04/30/2014 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
04/30/2014 EXCAVATION/LAYOUT REBAR & ZON Partial Approval STUB OUT LATER USE
1. MISSING FOOTER @ REAR PORCH PER DETAIL 14/S4-1
2. MISSING STEEL INTERIOR BEARING FOOTERS PER DETAIL 12/S4.1
3. EXCEPT FRONT PORCH DETAIL 13/S4.1 TOE DOWN