Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T14CM00018
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2014 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
04/30/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
04/30/2014 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | STUB OUT LATER USE 1. MISSING FOOTER @ REAR PORCH PER DETAIL 14/S4-1 2. MISSING STEEL INTERIOR BEARING FOOTERS PER DETAIL 12/S4.1 3. EXCEPT FRONT PORCH DETAIL 13/S4.1 TOE DOWN |