Inspection History Details
Inspection Status: Approved
Inspection History: FIRE - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/30/2014 | FIRE - FINAL | Approved | ||
| 01/27/2014 | FIRE - FINAL | Denied | 1. Clear tripping hazard from egress walkway east rear exit door. 2. Cover holes in break panel with blanks 3. Repair or replace exit sign/back up lighting over rear east exit door failed to work. 4. Front door as on approved plans state that they are doors with panic hardware to remain but in fact new doors and no panic hardware, need to add panic hardware or change approved plans. 5. Fire extinguisher post every 75' travel distance and 1 for every 1500 sq. foot of building a 2A 10BC type. 6. Address numbers posted on building need to be 12" in size 4622 - 4628. |