Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T14BU00465

Parcel: 141386620

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Permit Number - T14BU00465

Inspection Description - POOL/SPA FINAL/BARRIER

Inspection Status - Approved

Date Description Inspector Results Comments
06/16/2014 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
06/04/2014 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/04/2014 POOL/SPA FINAL/BARRIER Denied - EXPOSE AUTO FILL LINE TO VERIFY MINIMUM BURIAL DEPTH
- WINDOWS TO POOL ENCLOSURE TO BE SELF-CLOSING & SELF-LATCHING OR HAVE UL2017 ALARM
- U.V. PROTECT PVC FOR AUTO POOL FILL (PAINT)
- VACUUM BREAKER NEEDED FOR NEW HOSE BIB