Inspection History: MECHANICAL - FINAL

Permit Number - T13ME00109

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/16/2013 MECHANICAL - FINAL Approved IVRS - Inspection :*
09/13/2013 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
09/13/2013 MECHANICAL - FINAL Denied PROVIDE MIN CLEARANCE FROM SINGLE WALL CONNECTORS TO WOOD DOOR FRAME; 6" OR INSTALL B VENT W/ 1" CLEAR
09/11/2013 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/11/2013 MECHANICAL - FINAL Denied PVC IS CONSIDERED COMBUSTIBLE. USE COPPER PIPE OR B VENT FOR CLEARANCE REDUCTION. ANY FURTHER FAILED INSPECTIONS WILL RESULT IN A RE-FEE. SEE BOTH UNITS
09/09/2013 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
09/09/2013 MECHANICAL - FINAL Partial Approval 1. LINE SETS TO BE COATED FOR U.V. PROTECTION - ADHESIVES NOT ALLOWED
2. PROVIDE MINIMUM CLEARANCE FROM FLUE PIPE TO COMBUSTIBLES (SECONDARY DRAINS)
3. PROVIDE SCREWS AT FLUE PIPE