Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T13DV08890

Parcel: 113071920


Addresses:

1548 E HEDRICK DR


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T13DV08890

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
11/25/2013 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE:
INSP. HOLLANDER ON SITE.
WALKED PROPERTY, LOCATED SEVERAL DIFFERENT ISSUES.
EXTERIOR WALLS, ADOBE, STUCCO COVERING ON EXTERIOR.
3 BUILDINGS FLAT ROOFS. THESE BUILDING SHOW THE WORST DAMAGE AND DETERIORATION OF STUCCO AND ADOBE WALLS.
SCUPPERS COMMING FROM ROOF FOR DRAINAGE NOT PROPERLY INSTALLED, SECURED ALLOWS FOR EXTERIOR ELEMENTS TO ENTER IN BEHIND STUCCO AND ADOBE CAUSING DETERIORATION AND ADOBE TO CRUMBLE AND STUCCO TO SEPERATE FROM ADOBE.

MAJOR CHANGES TO PROPERTY.
PROPERTY SHOWS USE TO BE NURSING HOME. NOW SHOWS SEVERAL DIFFERENT AREAS HAVE BEEN CONVERTED INTO DWELLING UNITS.
STRUCTURAL: ADDED WALLS, REMOVED WALLS.
ELECTRICAL, POTABLE WATER HOT & COLD, BATHROOMS, BEDROOMS, SOME WITH NO EGRESS. KITCHENS IN ALL UNITS.

BUILDINGS SET UP HAD LONG HALLWAYS FROM ONE END TO THE OTHER, THESE ARE NOW ENCLOSED AND USED AS PATR OF THE UNIT. (DIFFERENT).

THERE ARE TWO CELLERS, MECHANICAL ROOMS, BASEMENTS?
WHICH WERE DUG OUT AFTER POUR OF FOUNDATION. TO MUCH DIRT REMOVED CAN SEE WHERE FOUNDATION SHOWS CRACKING, DETERIORATION, WHERE DIRT IS MOVING AWAY FROM FOUNDATION.
WOOD BEAMS, DETERIORATING SAGGING IN AREAS, APPEARS REPAIRS HAVE BEEN MADE TO TRY TO RE-SUPPORT DOES NOT APPEAR TO WORK AS WELL AS EXPECTED.

TALKED WITH MANAGEMENT FOR APPT. TO GO FARTHER INTO PROPERTY AND UNITS.
MONDAY 11/25/13