Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/03/2013 | INSP - INITIAL CODE ENFORCMENT | Approved | FIRE DAMAGE TO THE ROOF ASSEMBLY OF THE BEDROOM AREA, THERE IS DAMAGE TO TWO OF THE RAFTER/TRUSS SYSTEM WHICH SPANS ABOUT 16 TO 18 FEET FROM BLOCK WALLS. THE RAFTER'S ARE 2X8 WITH HALF THE SPAN TURNING INTO A TRUSS ASSEMBLY MADE UP OF A 2X6 UNDER NEATH NAIL TO THE 2X8 AND TWO PIECES OF PLY STRIPS NAILED ON EACH SIDE. THE ROOF PLANKING ¾ HAS CRACKS AND IS BURNT IN THE SAME AREA. THERE IS ALSO TWO OTHER 4X4 CUT OUT'S IN THE ROOF OPPOSITE SIDE OF THE FIRE DAMAGE AREA. THE FIRE DAMAGED AREA ABOVE THE EXIT DOOR HAS ONE JUNCTION BOX WITH BURNT EXPOSED WIRES, IN THE SAME AREA THERE IS FLEX CONDUIT WITH POSSIBLE HEAT DAMAGE. POWER WAS SHUT OFF AND METER RED TAGGED BY TEP. GAS IS OK PERMIT REQUIRED FOR ALL REPAIRS. THE UNIT IS CONDEMNED UNFIT TO OCCUPY |