Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date |
Description |
Inspector |
Results |
Comments |
| 07/03/2013 |
INSP - INITIAL CODE ENFORCMENT |
|
Approved |
Visited site, inspected,found as follows, water heater poses a safetyhazard to the public, has diffenences as the vent piping -none,no gas shut off, no cold water shut off,grass and weeds penitrating the combustion chamber, TPT valve not plumbed correctly. Main gas line has no shut off,has broken windows, outside outlet- no cover, not gfci. Cooler electrical is not to code- has open wiring and leaking. Also main service panel is inassessable, took pictures, will write notice of violation |