Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T13DV03872
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/04/2013 | INSP - INITIAL CODE ENFORCMENT | Approved | UNIT 49: VISITED SITE: M/H PARK. ADDED CARPORT WOOD DETERIORATED STRENGHT AND STABILITY COMPERMISED. ANIMAL WASTE ON GROUND. FENCING FALLING, LEANING NOT SECURED IN ANY MANNER. 0 EGRESS FROM BEDROOM. ADDITION. SEVERAL WINDOWS BOARDED FROM INTERIOR/EXTERIOR. ENTRY/EXIT STEPS DETERIORATED. 4 STEPS NO RAILS. PORCH LIGHT EXPOSED WIRING. COOLER LEAKS, COOLER HAZARDOUSLY WIRED, 14 AWG EXTENSION CORD SUPPLYS POWER TO BOTH COOLER PUMP, COOLER MOTOR RAN THROUGH WINDOW, WIRE SPLICED. ADDED 2 SEPERATE SUB-PANELS TO PEDESTAL. CONNECTIONS ?. AT THIS TIME INSP. PULLED PLUG ON COOLER. REMOVED HAZARDS, TALKED WITH OWNER SHOWED HAZARDS EXPLAINED NEEDS TO PROPERLY REPAIR. NO COOLING 24 HOURS TO REPAIR/OR BUY PORTABLE. CHIRPA NOTIFIED BY MANAGER CHIRPA AGREED TO HELP. FOLLOW UP 6/5/13. (MANAGER) |