Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T13DV03514
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2013 | INSP - INITIAL CODE ENFORCMENT | Approved | ELECTRICAL VIOLATIONS THERE IS A 400 AMP MASTER METERED SYSTEM WITH TWO 200 AMP PANELS ADJACENT TO THE METER LOCATION. 1. GROUNDING ELECTRODE CONDUCTOR SYSTEM IS INSTALLED CODE COMPLIANT 2. WORKING CLEARANCE IN FRONT OF SERVICE EQUIPMENT DOES NOT HAVE THE REQUIRED 36 INCHES WORKING SPACE 3. NO LABELING ON SERVICE EQUIPMENT 4. FILL UN USED OPENINGS IN THE PANEL 5. BROKEN PANEL COVER ON THE NORTH PANEL 6. MULTIPLE NEUTRALS CONDUCTORS PLACED UNDER THE SAME SCREW TERMINAL IN THE INTERIOR OF THE NORTH PANEL 7. EXPOSED AND DETERIORATED NON METALLIC SHEATHED CABLE FEEDING THE OVERHEAD LIGHT. 8. UNAPPROVED WIRING METHODS UNIT 1 NO DISCONNECT EQUIPMENT (NO PANEL W/ BREAKERS) NO CONDUCTOR PROTECTION DETERIORATED NONMETALLIC SHEATHED CABLE BEING USED AS A LIFE LINE OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR. NO GROUNDING ELECTRODE SYSTEM UNAPPROVED WIRING METHODS NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater- vent too low, no enclosure, copper used for gas line ABS is exposed, improper clean out connection UNIT 2 HARD WIRED LIFELINE (LIFE LINE NOT CODE COMPLIANT) NO GROUNDING ELECTRODE SYSTEM IMPROPER BREAKER FOR 220 RECEPTACLE MISSING HANDLE TIE OR REPLACE WITH TWO POLE TYPE NO LABELING Water Heater- vent too low, no enclosure, needs relief valve discharge pipe. copper used for gas line , ABS is exposed, improper clean out connection. UNIT 3 WORKING CLEARANCE SUPPORT POST IS DETERIORATED NO GROUNDING ELECTRODE SYSTEM NO LABELING Water Heater- vent too low, no enclosure, needs relief valve discharge pipe. copper used for gas line , ABS is exposed, improper clean out connection. UNIT 4 WORKING CLEARANCE LIFE LINE NOT CODE COMPLIANT NO GROUNDING ELECTRODE SYSTEM SUPPORT POST IS DETERIORATED NO LABELING Water Heater- no enclosure, ABS exposed, improper clean out connection. UNIT 5 NO GROUNDING ELECTRODE SYSTEM SUPPORT POST IS DETERIORATED WITH TERMITE DAMAGE WORKING CLEARANCE NO DEAD FRONT LIFE LINE NOT CODE COMPLIANT UNAPPROVED WIRING METHODS NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS Water Heater- no vent pipe ,no enclosure, needs relief valve discharge pipe, improper clean out connection. UNIT 6 NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE LIFE LINE NOT CODE COMPLIANT DETERIORATED NONMETALLIC SHEATHED CABLE BEING USED AS A LIFE LINE OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR LACK OF A FILLER PLATE IN DEAD FRONT UNAPPROVED WIRING METHODS NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS Water Heater-OK, ABS exposed, improper clean out connection. 8 x 10 addition UNIT 7 NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE FILL UN USED OPEN SPACES USING PVC WATER CONNECTORS IN CONDUIT OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR. UNAPPROVED WIRING METHODS NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater- no vent pipe ,no enclosure, ABS pipe needs paint UNIT 8 30 AMP DISCONNECT HAS INTERNAL PARTS THAT ARE DETERIORATED AND HAVE RUST NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE, VEGETATION OF RAZOR WIRE ADJACENT TO SYSTEM LIFE LINE NOT CODE COMPLIANT OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR UNAPPROVED WIRING METHOD NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS Water Heater- no enclosure, improper clean out connection. ABS pipe needs paint UTILITY ROOM / LAUNDRY ROOM TWO WASHERS AND TWO DRYERS ARE OUT DOOR AND EQUIPMENT IS NOT RATED FOR OUTDOOR USE. 60 AMP SERVICE IS UN ACCESSIBLE SODA MACHINES IS BLOCKING ACCESS. WORKING CLEARANCE UNPROTECTED RECEPTACLE BOX (NOT RATED FOR OUTDOOR USE) REAR OF UTILITY ROOM HAS 100 AMP PANEL. THE NEUTRALS ARE BONDED TO THE HOUSING.( NEUTRALS MUST BE ISOLATED) NO GROUNDING ELECTRODE SYSTEM NO LABELING FILL USED OPENINGS THIS PANEL BOARD IS NOT SUITABLE FOR APPLICATION NO LABELING OFFICE / TRAILER PEDESTAL HAS ONE PANEL BOARD AND TWO HM DISCONNECTS NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE SUPPORT POST IS DETERIORATED NONMETALLIC SHEATHED CABLE USE OUTDOOR AND IS DETERIORATED RECEPTACLE BOX (NOT RATED FOR OUTDOOR USE) UNAPPROVED WIRING METHODS NO LABELING UNIT 9 FILL UN USED OPENINGS EXPOSED NONMETALLIC SHEATHED CABLE NO GROUNDING ELECTRODE SYSTEM DISCONNECT HAS OPEN HOLE OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR UNAPPROVED WIRING METHODS SUPPORT CONCRETE BASE CRACKED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater-no enclosure, needs relief valve discharge pipe. improper clean out connection. Storage issues. UNIT 10 OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR GROUNDING ELECTRODE SYSTEM NOT INSTALLED CORRECTLY INTERNAL PARTS OF THE DISCONNECT ARE DETERIORATED UNAPPROVED WIRING METHOD (3 METERS ARE FEED BY ONE MULTIPLE LUG AT THE OVER HEAD LOCATION. (NO WEATHER HEAD PER DISCONNECT) SUPPORT CONCRETE BASE CRACKED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT improper clean out connection. ABS pipe needs paint UNIT C ALL CONDUCTORS ARE WHITE NO GROUNDING ELECTRODE SYSTEM UNAPPROVED WIRING METHODS RECEPTACLE NOT INSTALLED CODE COMPLIANT PER ENVIRONMENT OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR SUPPORT CONCRETE BASE CRACKED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT improper clean out connection. UNIT 11 OVERHEAD FEEDERS NOT TO CODE HEIGHT DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE UNAPPROVED WIRING METHODS SUPPORT POST IS DETERIORATED DETERIORATED NONMETALLIC SHEATHED CABLE BEING USED AS A LIFE LINE NO GROUNDING ELECTRODE SYSTEM JUMPER WIRE INSTALLED IN THE TWO POLE BREAKER (DISCONNECT NOT INSTALLED PER MANUFACTURES INSTRUCTIONS. THIS PANEL BOARD IS NOT SUITABLE FOR APPLICATION SUPPORT POST IS DETERIORATED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT improper clean out connection. ABS pipe needs paint UNIT 12 IMPROPER DISCONNECT HEIGHT LIFE LINE HARD WIRED (LIFE LINE NOT CODE COMPLIANT) DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE UNAPPROVED WIRING METHODS NO GROUNDING ELECTRODE SYSTEM OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR IMPROPER JUNCTION BOX BACKER BOARD LOOSE WORKING CLEARANCE NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS storage, debris issues, water heater- copper used for gas line. improper clean out connection. UNIT B 30 AMP DISCONNECT HAS JUMPER BACK FEEDING OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO GROUNDING ELECTRODE SYSTEM UNAPPROVED WIRING METHODS DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE SUPPORT POST IS DETERIORATED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT improper clean out connection. UNIT 14 NO GROUNDING ELECTRODE SYSTEM METAL RACEWAY POSSIBLY HAS GROUNDING ELECTRODE CONDUCTOR NOT BONDED IF INSTALLED PER CODE. SUPPORT POST IS DETERIORATED NO LABELING Water Heater- no vent pipe, no enclosure, improper clean out connection. ABS pipe needs paint UNIT 15 NO GROUNDING ELECTRODE SYSTEM NO LABELING ABS sewer pipe needs paint UNIT 16 NO GROUNDING ELECTRODE SYSTEM SUPPORT POST IS DETERIORATED DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE WORKING CLEARANCE IMPROPER CORD CAP EXPOSE RECEPTACLE OUTLET BOX NO LABELING ABS sewer pipe needs paint UNIT 17 FILL USED OPENINGS SUPPORT POST IS DETERIORATED SUPPORT CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE HARD WIRED LIFE LINE (LIFE LINE NOT CODE COMPLIANT) OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS Water Heater- vent too low, no enclosure, copper used for gas line. improper clean out connection. sewer pipe needs paint UNIT 18 Water Heater- no enclosure, needs relief valve discharge pipe, copper used for gas line SUPPORT POST IS DETERIORATED SUPPORT CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE HARD WIRED LIFE LINE (LIFE LINE NOT CODE COMPLIANT) OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR FILL USED OPENINGS NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS UN MARKED DISCONNECT SAME LOCATION AS UNITS 17, 18 60 AMP SUPPORT POST IS DETERIORATED SUPPORT CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE HARD WIRED LIFE LINE OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS WORKSHOP SUPPORT POST IS DETERIORATED SUPPORT CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM EXPOSE RECEPTACLE OUTLET BOX METAL CONDUIT RACEWAY HAS SEPARATED RECEPTACLE HAS NO OVER CURRENT PROTECTION OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS UNKNOWN LOCATION OF EQUIPMENT PANEL UNIT 19 NOT CONNECTED TO DISCONNECT AT POLE. NOT PROPER GROUNDING ELECTRODE SYSTEM OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR SUPPORT CONCRETE BASE CRACKED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT vacant no Water Heater visible. ABS sewer pipe needs paint,improper clean out connection. TRENCHING IN AREA UNIT 20 USING PVC WATER FITTING IN RACEWAY NOT PROPER GROUNDING ELECTRODE SYSTEM OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR SUPPORT CONCRETE BASE CRACKED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater- no enclosure, improper clean out connection. UNIT 21 CONDEMNED DUE TO DEFECTIVE AND HAZARDOUS DISCONNECT THE PARK MAINTENANCE DID REMOVE THE DISCONNECT. THE UNIT WAS VACANT A VIOLATION NOTICE WAS ISSUED ON SITE OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO GROUNDING ELECTRODE SYSTEM SUPPORT POST IS DETERIORATED DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater- disconnected, no vent ,no discharge pipe, ABS sewer pipe needs paint UNIT 22 30 AMP DISCONNECT HAS INTERNAL PARTS THAT ARE DETERIORATED OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO GROUNDING ELECTRODE SYSTEM SUPPORT POST IS DETERIORATED DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE UNAPPROVED WIRING METHOD (JUMPER WIRE INSTALLED) NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater- disconnected, cleanout has vent sewer pipe needs paint UNIT 23 30 AMP DISCONNECT HAS INTERNAL PARTS THAT ARE DETERIORATED OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO GROUNDING ELECTRODE SYSTEM SUPPORT POST IS DETERIORATED DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE UNAPPROVED WIRING METHODS JUMPER WIRE INSTALLED NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater- vent ok ,no enclosure, needs relief valve discharge pipe ABS pipe needs paint UNIT 24 30 AMP DISCONNECT HAS INTERNAL PARTS THAT ARE DETERIORATED OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR NO GROUNDING ELECTRODE SYSTEM SUPPORT POST IS DETERIORATED DETERIORATED EXPOSED NONMETALLIC SHEATHED CABLE UNAPPROVED WIRING METHOD 9 JUMPER WIRE INSTALLED THIS IS THE DISCONNECT THAT WAS REPLACED BY PARK MAINTENANCE NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater- no enclosure, sewer connection needs paint UNIT 25 NOT PROPER GROUNDING ELECTRODE SYSTEM OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR SUPPORT CONCRETE BASE CRACKED FILL USED OPENINGS IMPROPER RISER NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT Water Heater not visible, sewer pipes need paint,small trench in area UNIT 26 NOT PROPER GROUNDING ELECTRODE SYSTEM OVERHEAD CONDUCTORS ARE DETERIORATED, NOT RATED FOR OUTDOOR SUPPORT CONCRETE BASE CRACKED IMPROPER RISER IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS SEPARATE GROUNDS AND NEUTRALS NO LABELING LIFE LINE NOT CODE COMPLIANT dilapidated ramada attached to unit improper clean out connection. UNIT 27 SUPPORT CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM FILL USED OPENINGS IN DEAD FRONT NO LABELING OVERHEAD CONDUCTORS ARE DETERIORATED IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS NO LABELING LIFE LINE NOT CODE COMPLIANT ABS pipe needs paint UNIT 28 SUPPORT CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM FILL USED OPENINGS IN DEAD FRONT NO LABELING OVERHEAD CONDUCTORS ARE DETERIORATED IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS NO LABELING LIFE LINE NOT CODE COMPLIANT Water Heater-no enclosure, needs relief valve discharge pipe, copper used for gas line,improper clean out connection. sewer pipe needs paint, small amount of debris. UNIT 29 OVERHEAD CONDUCTORS ARE DETERIORATED IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS PROPER LIFE LINE REQUIRED NO GROUNDING ELECTRODE SYSTEM NO LABELING SUPPORT CONCRETE BASE CRACKED LIFE LINE NOT CODE COMPLIANT ABS pipe needs paint UNIT 30 NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE PROPERLY STRAP RISER IMPROPER SPLICE CONNECTIONS OVERHEAD CONDUCTORS ARE DETERIORATED NO LABELING SUPPORT CONCRETE BASE CRACKED IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS LIFE LINE NOT CODE COMPLIANT vacant, no water heater ABS sewer pipe needs paint UNIT 31 SUPPORT POST IS DETERIORATED AND CONCRETE BASE CRACKED NOT SECURED NO GROUNDING ELECTRODE SYSTEM OVERHEAD CONDUCTORS ARE DETERIORATED IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS FILL USED OPENINGS NO LABELING LIFE LINE NOT CODE COMPLIANT Water Heater- no enclosure, copper used for gas line, improper clean out connection. sewer pipe needs paint, Arizona room attached to unit UNIT 32 CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM NO LABELING IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS HUB HARDWARE IS NOT CODE COMPLIANT LIFE LINE NOT CODE COMPLIANT ABS sewer pipe needs paint, enclosed porch attached to unit UNIT 33 CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM NO LABELING OVERHEAD CONDUCTORS ARE DETERIORATED IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS FILL USED OPENINGS REPLACE CORD CAP LIFE LINE NOT CODE COMPLIANT Water Heater- no vent pipe, no enclosure, copper used for gas line ABS pipe needs paint, improper clean out connection. UNIT 34 IMPROPER SPLICE CONNECTIONS TO THE OVERHEAD FEEDERS SUPPORT POST IS DETERIORATED AND CONCRETE BASE CRACKED NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE NO LABELING OVERHEAD CONDUCTORS ARE DETERIORATED FILL USED OPENINGS PROPER LIFE LINE REQUIRED SECURE RISER LIFE LINE NOT CODE COMPLIANT Water Heater- no enclosure, copper used for gas line ABS pipe needs paint NOTES: ALL EXPOSED SEWER CONNECTIONS (ABS) NEED PAINT. THE OTHER UNITS 4,5,9,A,C,10 HAVE ABS THAT IS NOT VISIBLE. LIGHT WEEDS,LIGHT TRASH THROUGHOUT PROPERTY, WITH A FEW EXCEPTIONS. ONE DEAD TREE. SOME STORAGE ISSUES. TRENCHING NEEDS BACKFILLED IN SOME AREAS 3 ADDITIONS ATTACHED TO UNITS 1 DILAPIDATED AWNING. ZONING VIOLATIONS THE PLACITA DEL ARROYO RV / RESIDENTIAL TRAILER PARK HAS BEEN EXPANDED TO ACCOMMODATE ADDITIONAL MOBILE HOMES. RESEARCH AT PLANNING AND DEVELOPMENTS SERVICES FOUND A PLOT PLAN WITH 11 MOBILE UNITS, TWO DWELLING UNITS AND A TOOL SHOP/ BATH HOUSE. |