Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T13DV01820
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/25/2013 | INSP - INITIAL CODE ENFORCMENT | Approved | MARTIN SANCHEZ (OCCUPANT 520-551-2337) JEFF WEHAGE (MANAGER 981-7835 CELL) (OFFICE 520-408-6977) TFD REQUEST FOR INSPECTOR / ELECTRICAL FIRE: VISITED SITE MET WITH OWNER WHO MENTIONED HE HAS BEEN LIVING AT THE UNIT FOR 5-6 MONTHS. TODAY HIS POWER WENT OFF, WENT TO THE SERVICE PANEL TO TURN POWER BACK ON AFTER FINDING ALL BREAKERS IN THE OFF POSITION. MARTIN SHOWED ME ONE PARTICULAR BREAKER THAT WHEN TURNED BACK ON CAUSED ARCHING AT THE LIGHT FIXTURE NEAR THE REAR DOOR, MINOR FLAMES AND SMOKE AND BREAKER POPED BACK OFF. UPON MY ARRIVAL I FOUND ALL BREAKERS OFF, TRAILER UNPLUGGED AT THE DAMAGED PEDESTAL. MARTIN MENTIONED HE DOESN'T OWN THE TRAILER YET, IT IS A LEASE TO OWN TRAILER AND TRAILER PRESENTLY OWNED BY THE TRAILER PARK. CONTACTED MANAGER JEFF WEHAGE WHO MENTIONED HE WOULD BE HERE SHORTLY. CALLED AND SPOKE WITH INSPECTOR JAMES HURD TO DETERMINE IN THIS CASE WHETHER THE PARK OWNER OR OCCUPANT WOULD RECEIVE THE NOV, WE BOTH AGREED THE PARK OWNER WOULD GET THE NOV, INSPECTOR HURD LATER SHOWED UP TO THE PARK, SHORTLY AFTER THE MANAGER ARRIVED. INSPECTION FOUND SEVERAL ELECTRICAL ISSUES: >PEDESTAL FRONT COVER DAMAGED AND NOT CLOSING PROPERLY >SUBPANEL ON SOUTH SIDE OF TRAILER DOES NOT HAVE A WEATHER PROOF COVER, FOUND MULTIPLE CUT WIRES INSIDE, ILLEGAL SPLICE AND DBL LUGGING. FOUND WHERE ARCHING HAD OCCURRED INSIDE THE BOX. > FOUND ILLEGAL SPICING UNDER THE TRAILER NEAR THE HOW WATER HEATER ROOM, ARCHING EVIDENCED FROM THE BURNT WIRES. > INTERIOR WIRING FOR THE REFRIGERATOR FOUND WIRE CUT TO THE OUTLET, WIRE LEFT OUTSIDE THE WALL AND TAPED AND EXTENSION CORD RUN TO A OUTLET FURTHER AWAY TO PLUG IN THE REFRIGERATOR. >FOUR OUTLETS ABOVE THE CABINETS NOT WORKING PER THE OCCUPANT (1) OUTLET DAMAGED COMPLETELY. TWO OULETS IN THE LIVINGROOM CONTINOUSLY POPPING THE BREAKER >ALL LIGHT FIXTURES NOT COMPLETED. PLUMBING ISSUES: >NO GAS / NO HEAT (HEATING UNIT IS GAS ) >HOW WATER HEATER DAMAGED DETERIORATING, RED TAGGED BY S/W GAS. NO HOT WATER SINCE OCCUPANT MOVED IN. > INTERIOR PLUMBING EXPOSED IN THE BATHROOM AREA. >EXTERIOR VENT TERMINATED BELOW THE BOTTOM OF WINDOW. (NOT EXTENTED HIGH ENOUGH) STRUCTURAL ISSUES: >INTERIOR SUB FLOORING DAMAGED, DETERIORATED OR MISSING. DAMAGED IN LIVINGROOM, KITCHEN AND HALLWAY, MISSING IN THE BATHROOM (EXPOSED TO THE ELEMENTS AND ALLOWING RODENTS TO ENTER THE STRUCTURE) >EXTERIOR WALL STUDS CUT FOR A/C WINDOW ROOM UNITS. UNITS REMOVED AND METAL SIDING NEVER REPLACED. >EXTERIOR STAIRS TO REAR DOOR DELAPIDATED >EXTERIOR DOOR DAMAGED BEYOND REPAIR > EXTERIOR SIDING AT ROOF LINE DELAPIDATED (NEEDS REPAIRS UNIT SHUT DOWN FOR NO GAS, NO ELECTRIC, NO HEAT. MANAGER CONTACTED RED CROSS TO HOUSE THE OCCUPANTS, TWO ADULTS, TWO CHILDREN. EXPLAINED TO MANAGER THAT HE NEEDS TO MAKE ALLREPAIRS TO THE STRUCTURE, OR STRUCTURE SHOULD BE DEMO'ED. UNIT POSTED "UNSAFE TO OCCUPY". MANAGEMENT SECURED REAR DOOR WHILE ON SITE WAITING FOR RED CROSS. |