Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T13DV00508

Parcel: 10706008A


Addresses:

1130 W MIRACLE MILE


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T13DV00508

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
01/23/2012 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE IN RESPONSE TO TFD REQUEST FOR INSPECTOR, HAZARDOUS LIVING CONDITIONS. MET WITH TPD OFFICER RUSS POPE WHO INFORMED ME STRUCTURE WAS OWNED AT ONE TIME BY GOSPEL RESCUE MISSION, SERVED BATTERED WOMEN WHO LIVED ON SITE AND EVERY ONE WAS FED AT A COMMISSARY, THE STRUCTURE AT THE NORTH END OF THE PROPERTY. COMMISSARY WAS SHUT DOWN, BEING USED FOR STORAGE, AND THE UNITS ARE BEING RENTED OUT TO INDIVIDUALS ON A MONTH TO MONTH BASIS. SOME OF THE STRUCTURES WERE BEING REMODELED. TPD WANTED TO KNOW IF THE STRUCTURES WERE HAZARDOUS AND IF PEOPLE COULD STAY THERE. OWNER WAS ONSITE BUT BEING QUESTIONED BY TPD OFFICERS.
I DECIDED TO WALK THE WEST UNITS TO START, TPD OFFICERS HELPED WITH THE ENTRY TO THE UNITS, STARTED WITH THE SOUTH UNIT WORKING OUR WAY NORTH. FIRST TWO UNITS WERE VACANT, FOUND FRONT PORCH AND DOORS REMOVED EXPOSING MUD ADOBE BLOCK. INTERIOR WALLS WERE ALSO ADOBE, FOUND FRAMED WALLS BEING ADDED, ELECTRICAL, PLUMBING AND SEWER BEING ADDED, AND FLOOR HAD BEEN SAW CUT TO EXPOSE THE SEWER. THIRD UNIT WAS OCCUPIED AND HAD MULTIPLE LIVING CONDITION ISSUES AND BLOCKED EXITS. FORTH UNIT WAS THE SAME WITH MULTIPLE LIVING CONDITIONS AND NO KITCHEN WITH TENANTS COOKING ON THE DRESSER AND MULTIPLE CORDS ALONG WITH THE REFRIGERATOR INTO ONE STRIP CORD. THIRD UNIT HAD ONLY PARTIAL ELECTRIC. CHECKED THE MAIN ELECTRICAL (THREE PHASE SYSYTEM) AND THE ELECTRICAL RUNNING TO THE UNITS AND AGIN FOUND MULTIPLE VIOLATIONS. DUE TO THE CIRCUMSTANCES I FELT A FOLLOW UP INSPECTION DURING DAY TIME HOURS WOULD BE BEST AND AVOID A SHUT DOWN THAT EVENING. I CONTACTED RICHARD VIDAL TO SET UP A INSPECTION THE FOLLOWING MORNING. I INFORMED OFFICER POPE OF MY FINDINGS AND EXPLAINED THAT WE SET UP A INSPECTION FOR APPROX 8:00 AM THE FOLLOWING MORNING SO THAT TPD COULD BE ON SITE. I ALSO EXPLAINED THAT DUE TO THE MULTIPLE ISSUES IT WAS LIKELY WE WOULD HAVE TO SHUT THE ENTIRE PARK DOWN. THERE ARE APPROX 20 UNITS, 9-10 OCCUPIED AND THE COMMISSARY.