Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2015 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 12/30/2014 | ROOF NAILING | Partial Approval | IVRS - Inspection :* | |
| 12/30/2014 | ROOF NAILING | Partial Approval | NOTES: 2, 3, 4, 5, & 6 FROM PREVIOUS NAILING OK | |
| 12/03/2014 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/03/2014 | ROOF NAILING | Not ready for Inspection | 1. PER KEYNOTE 25 LS90, EACH SIDE OF BEAM 2. PROVIDE DETAIL FOR PORCH LEDGER ATTACHMENTS 3. PROVIDE AS BUILT TO ENTRY CHARGE OR BUILT TO PLAN 4. PROVIDE DETAIL FOR TJI ATTACHMENT TO BEARING WALLS 5. PROVIDE STAMPED APPROVED TRUSS CALCS 6. SUBMIT AS BUILT TO ALL CHANGES ***STOPPED INSPECTION*** |