Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T13CM07453

Parcel: 122010050


Addresses:

1421 N LOUIS AV #01


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T13CM07453

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/12/2014 ELECTRIC - INTERMEDIATE Approved PER ELEC FINAL
06/05/2014 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/05/2014 ELECTRIC - INTERMEDIATE Denied PROVIDE APPROVED CABLE CONNECTORS AT ROMEX TO BOX CONNECTIONS. SEPARATE BUNDLE OF WIRE AT SERVICE & SECURE WITHIN 12" OF PENETRATION THRU WALL. SECURE ALL WATER PIPING. PROVIDE NAIL PLATES AS NEEDED. PROVIDE R8 DUCT INSULATION IN ATTIC & EXPOSED DUCT ON ROOF. ALL SMOKE DETECTORS TO BE HARD WIRED. ALL PLUMBING TO BE UNDER TEST. PROVIDE APPROVED HANGERS TO SUPPORT PLUMBING. DO NOT USE PLUMBERS TAPE. PROVIDE BUSHINGS AT SUBPANELS.