Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2014 | ELECTRIC - INTERMEDIATE | Approved | PER ELEC FINAL | |
| 06/05/2014 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 06/05/2014 | ELECTRIC - INTERMEDIATE | Denied | PROVIDE APPROVED CABLE CONNECTORS AT ROMEX TO BOX CONNECTIONS. SEPARATE BUNDLE OF WIRE AT SERVICE & SECURE WITHIN 12" OF PENETRATION THRU WALL. SECURE ALL WATER PIPING. PROVIDE NAIL PLATES AS NEEDED. PROVIDE R8 DUCT INSULATION IN ATTIC & EXPOSED DUCT ON ROOF. ALL SMOKE DETECTORS TO BE HARD WIRED. ALL PLUMBING TO BE UNDER TEST. PROVIDE APPROVED HANGERS TO SUPPORT PLUMBING. DO NOT USE PLUMBERS TAPE. PROVIDE BUSHINGS AT SUBPANELS. |