Permit: T13CM07442

Parcel: 132100490

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/22/2014 FRAMING Approved IVRS - Inspection :*
09/19/2014 FRAMING Partial Approval IVRS - Inspection :* PENDING ALL TRADES
09/11/2014 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/05/2014 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/05/2014 FRAMING Denied 1. EXTERIOR BOX'S NOT PROPERLY INSTALLED/SECURED
2. REMOVE PAPER TO ALLOW FOR ROOF NAILING INSPECTION
3. B-VENT NOT PROPERLY INSTALLED MINIMUM 1" TO COMBUSTIBLES
4. BOOT BOX'S TO BE FRAMED ON MINIMUM 3 SIDES
5.PLUMBING NOT ON TEST
6. ALL DUCT IN ATTIC TO BE R-8
7. THIS INSPECTION IS NOT COMPLETE TOO MANY ITEMS TO LIST