Permit: T13CM06515

Parcel: 133412500


Addresses:

9209 E BAKER ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/29/2013 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/28/2013 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/28/2013 ELECTRIC - FINAL Denied ANY SPLICE IN HIGH VOLTAGE WIRING MUST BE DONE IN A J BOX ABOVE KITCHEN COUNTERS. PROVIDE THE PROPER CONNECTOR AT RECEPTACLE IN CABINET ABOVE STOVE & CORD TO FURNACE. COVER PLATE MISSING AT DRYER RECEPTACLES IN BEDROOM. PROVIDE A GLOBE FOR LIGHT FIXTURE IN LAUNDRY ROOM. CAP OFF OPEN CONDUCTORS IN MASTER BATH LIGHT. PROVIDE A SMOKE DETECTOR IN EACH BEDROOM. INSTALL DETECTORS PER INSTALL INSTRUCTIONS FOR LOCATION. USE APPROVED CONDUIT FOR DIRECT BURIAL TO RECEPTACLES AROUND POOL. ALL OUTDOOR RECEPTACLES TO BE GFI.