Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/04/2013 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/02/2013 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/02/2013 | EXT METAL CLIPS/EXT SHEATHING | Denied | - RAFTERS MISSING BEARING WALL PER APPROVED ROOF TRUSS LAYOUT - LATERAL BRACE TRUSSES - COIL STRAP PATIO HEADER PER PLAN 6/SD1.3A - 2-2X4 CRIPPLES NEEDED UNDER GARAGE GIRDER ABOVE WINDOW - NAIL PROTECT PLUMBING WITHIN 1 1/2" ON EXTERIOR WALL BOTTOM PLATES - ANCHOR BOLTS MISSING FRONT SHEAR WALL - NAIL SHEAR TRANSFER PER 14/SD1.3C **STOPPED INSPECTION, TOO MANY ITEMS TO LIST** |