Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T13CM06174
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/15/2014 | MECHANICAL - INTERMEDIATE | Approved | ||
05/09/2014 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
05/09/2014 | MECHANICAL - INTERMEDIATE | Partial Approval | CAN LIGHT ABOVE TUB & SHOWER SHALL BE LISTED FOR WET LOCATION. PROVIDE PROPER CONNECTION FOR RECEPTACLE AT LOW VOLTAGE. ADD SUPPORT CLAMPS 1' FROM MAIN ELECTRIC PANEL. SECURE WIRE TO CAN LIGHT@ TOILET. KIT EXHAUST FAN NOT YET INSTALLED. SINGLE WALL VENT @ FAN REQ'S 6" FROM COMBUSTIBLE. INSTALL JOIST HANGER NAILS IN FHA STRAPS AT 3" BORE THROUGH TOP PLATE. INSPECTION REQ'S FOR TUB INSTALL & CLOSET (?). REMOVE ADHESIVE TAPE FROM PEX TUBING. OK TO COVER WALLS AFTER CORRECTING. | |
05/06/2014 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
05/06/2014 | MECHANICAL - INTERMEDIATE | Partial Approval | PVC PRIMER REQ, COMPLETE VENTS. APPROVED CLAMPS. ACCESS DOOR LIGHT. DISCONN CLEARANCE |