Permit: T13CM06095

Parcel: 133250760


Addresses:

8634 E COLETTE ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/27/2014 MECHANICAL - FINAL Approved IVRS - Inspection :*
01/27/2014 MECHANICAL - FINAL Approved SECURE BLOCKS W/ MASTIC TO ROOF. PAINT ALL PVC TO PROTECT AGAINST UV DAMAGE
11/01/2013 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/01/2013 MECHANICAL - FINAL Denied TIGHTEN LOOSE ELEC CONNECTIONS. CANNOT ACCESS ELEC DISCONNECT. SUPPORT PVC EVERY 4' & TERMINATE TO WITHIN 6" OF THE GROUND. BLOCK & CLAMP LOW VOLTAGE ELEC CONDUIT. 96,000 BTU FURNACE REQUIRES 3/4" PIPE 80' FROM METER. OK TO CHANGE TE4E IN CLOSET TO 3/4X3/4X1/2. PROVIDE A TEST ON ALL NEW PIPING.