Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T13CM06058

Parcel: 141097630


Addresses:

7980 S DOLPHIN WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/06/2014 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/02/2014 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/02/2014 EXT METAL CLIPS/EXT SHEATHING Denied - RETRO NEEDED FOR OVERSPALLED HOLD-DOWNS
- COIL STRAP SHORT BELLY BAND
- DOUBLE UP COIL STRAP AT STAIRWAY PER PLAN
- EQUIVILANCY FOR HANGERS NOT TO PLAN
- ANCHOR BOLTS PER SHEAR PLAN
- NAIL OFF BOTTOM CHORD OF GABLE END TRUSSES PER PLAN
- NAIL PROTECT PLUMBING TO CODE