Permit: T13CM05994

Parcel: 141097730

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/23/2013 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/22/2013 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/22/2013 EXT METAL CLIPS/EXT SHEATHING Denied - RAT RUN OF 6' - 0" FOR 3/SD1.2A
- DIAGONAL BRACE AT GABLE TRUSS PER 5/SD1.36
- ANCHOR BOLTS NEEDED PER SHEAR WALL SCHEDULE
- A35 NEEDED AT BLOCK T PLATE 2ND FLOOR