Permit: T13CM05993

Parcel: 141097700


Addresses:

8008 S DOLPHIN WY

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
02/04/2014 ROOF NAILING Approved IVRS - Inspection :*
01/08/2014 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/08/2014 ROOF NAILING Denied - STRAP OR NAIL OFF TOP OF BELLY BAND TO BOTTOM PLATE OF 2ND FLOOR WALLS
- INSULATE 2ND FLOOR BUMPOUTS
- ANCHOR BOLT NEEDED KITCHEN SHEAR WALL #7
- NAIL BLOCKING THROUGH ROOF SHEATHING PER 5/SD1.3B