Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
Permit Number - T13CM05958
Inspection Description - PLUMBING - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/22/2013 | PLUMBING - FINAL | Not ready for Inspection | 1. You have an addressing problem. Permit is for #02- gas is on. Number 03 or "C" is correct address. I will leave a gas card, but you need to correct the address and recall 03090 final. | |
10/18/2013 | PLUMBING - FINAL | Denied | 1. UNDERGROUND OK TO COVER 2. PRESSURE TEST OK 3. NEED ACCESS TO ALL AREAS OF NEW PIPING 4. NEED ACCESS TO ROOF |
|
10/16/2013 | PLUMBING - FINAL | Not ready for Inspection | 1. Gas line covered without inspection. Black iron pipe may not be installed below grade. Require emergency shut off valve at building. Require bond between water and gas piping. Require access to the roof. |