Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2013 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/24/2013 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 09/24/2013 | ELECTRIC - FINAL | Denied | PROPERLY INSTALL SMOKE DETECTORS WITH THE 2 SCREWS PROVIDED PLUS MIN 3' FROM CEILING FAN BLADES. EXPOSED WIRING IN MASTER BATH NOT TO CODE. REINSTALL SWITCH AT ENTRY. REMOVE CORD & PLUG LIGHT FIXTURES AT REAR OF HOUSE. WIRING IN PANTRY NOT TO CODE. EXPOSED ROMEX AT REAR OF HOUSE UNPROTECTED & WEATHERED, PROVIDE CONDUIT OR REMOVE. OUTDOOR RECEPTACLES TO BE GFI WITH WATERPROOF COVER. REMOVE OPEN WIRING AT SLIDING GLASS DOOR. ALL UNGROUNDED 3 PRONG RECEPTACLES MUST BE REPLACED W/ TWO-PRONG. REPLACE BROKEN COVER PLATE AT POOL PUMP. SECURE CONDUITS AT WEST WALL. WIRING IN SHED NOT TO CODE. HAVE A LICENSED ELECTRICIAN MAKE NECESSARY REPAIRS. |