Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
10/02/2013 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
10/01/2013 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
10/01/2013 PLUMBING - ROUGH, SOIL Partial Approval - RECALL FOR SEWER TIE-IN
- INSTALL FOAM WRAPS
09/27/2013 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/26/2013 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/26/2013 PLUMBING - ROUGH, SOIL Denied P3104; VENT CONNECTION TO HORIZ DRAIN SHALL CONNECT ABOVE CENTER LINE. WYE PATTERN FITTINGS REQUIRED ON HORIZ DRAIN PIPING. SAN TEE ON VERTICAL RISERS SLIP NUTS REQUIRE ACCESS. P3201; PROVIDE SUPPORT AND 10' TEST WCO SHOWN AT TOILET
09/25/2013 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/25/2013 PLUMBING - ROUGH, SOIL Denied INSTALL AS ILLUSTRATED W/ VERTICAL VENTS & PROPER USE OF FITTINGS. SLOPE AND 10' OF HEAD.