Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2014 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/05/2014 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/02/2014 | BUILDING - FINAL | Denied | GAS PRESSURE TEST IS REQUIRED | |
| 05/23/2014 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/23/2014 | BUILDING - FINAL | Not ready for Inspection | 1. DISHWASHER DRAIN MUST BE LOOPED UP TO COUNTER TOP OR HAVE AIR GAP FIXTURE INSTALLED 2. OUTLET LEFT OF RANGE MUST BE GFCI PROTECTED 3. ISLAND MUST HAVE AT LEAST ONE OUTLET 4. EXTERIOR ELECT OUTLETS MUST BE GFCI PROTECTED 5. HOSE BIBS MUST HAVE VACUUM BREAKER 6. GASLINE PRESSURE TEST MUST BE WITNESSED BY INSPECTOR |