Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 11/25/2013 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
PER PLMB FINAL - RCAMACHO |
| 09/13/2013 |
PLUMBING - GAS PRESSURE TEST |
|
Partial Approval |
IVRS - Inspection :* |
| 09/13/2013 |
PLUMBING - GAS PRESSURE TEST |
|
Partial Approval |
BONDING REQUIRED. CARBON MONOXIDE DETECTOR REQUIRED. VENT AT MASTER COOL IS OK. OTHER B VENT REQUIRES CLEARANCE FROM SWAMP COOLER. BELOW GRADE PIPING OK. PLAN TO SHOW ENTIRE SYSTYEM. RELIEF VALVE TO BE OPERATIONAL W/ OUT TRAPS. SECURE VENT CONNECTORS. PEX REQ 6" CLEAR FROM VENT. |
| 09/11/2013 |
PLUMBING - GAS PRESSURE TEST |
|
Not ready for Inspection |
IVRS - Inspection :* |